ROBUST SYSTEM PUMPS TO SEPARATE BIOMOLECULES FROM AQUEOUS AND ORGANIC SAMPLES

The system pump capabilities can be extended

• Pumps are constructed of PEEK polymer, the same material used in chromatography tubing
• Incorporate buffer inlets for multiple buffer selection
• Add a buffer-blending module for automated method scouting

SAMPLE LOADING SOLUTIONS SPANNING LARGE VOLUME RANGES AND THROUGHPUT REQUIREMENTS

• Use standard fixed-size sample loops and dynamic loops
• Perform automated, accurate, and reproducible multiple injections (5 µl–5 ml) using an autosampler
• Use a sample loading pump (flow rates of up to 100 ml/min) and an air sensor for:
– Loading of large sample volumes directly to the column
– Extending the life span of system pumps

VARIOUS COLUMN CONFIGURATIONS FOR COLUMN SCOUTING AND REDUCED NEED TO RE-PLUMB

• Add a single column switching module to connect up to five columns
• Add multiple column switching valves
– For multi-dimensional purification
– For reverse flow capability, which is ideal for column cleaning

UV MODULES THAT COME STANDARD WITH CONDUCTIVITY MONITORS PROVIDE OPTIMAL RESULTS

• The single-wavelength detector module utilizes an innovative LED light source that offers extended lamp life
• The multi-wavelength detector module can monitor up to four wavelengths simultaneously between 190–800 nm

MULTIPLE SAMPLE COLLECTION OPTIONS TO COLLECT EVERY DROP OF YOUR PRECIOUS PURIFIED SAMPLE

• Use the BioFrac™ fraction collector — choose from rack options such as 96-well microtiter plates, standard 12 mm tubes, 15 and 50 ml conical tubes
• Add one or more 12-port outlet modules to collect your sample into any other types of vessel

DUAL-GRADIENT PUMP SYSTEM

ACCURATE GRADIENTS FOR HIGH-RESOLUTION SEPARATIONS FOR ANY APPLICATION

Includes two gradient pumps and a mixer module to create precise gradients from two buffers.

  • Available in 0.001–10 ml/min or 0.01–100 ml/min formats
  • Up to 3,650 psi and 1,450 psi for the 10 ml/min and 100 ml/min pumps, respectively
  • Used with a wide range of media, from soft, large bead media to small, rigid media

DUAL-GRADIENT PUMP SYSTEM WITH BLENDING QUARTENARY VALVE

AUTOMATED GRADIENTS AND BLENDING FOR RAPID SCOUTING AND METHOD DEVELOPMENT

Includes two gradient pumps, a mixer module, and a quaternary valve for buffer-blending and scouting applications.

  • Available in 0.001–10 ml/min (max. 3,650 psi) and 0.01–100 ml/min (max. 1,450 psi) formats
  • Automated gradient and buffer-blending capabilities
  • Gradient separations at different pH values for rapid method development
  • Flow rates of up to 20 ml/min and 200 ml/min for the 10 ml/min and 100 ml/min pumps, respectively

DUAL-GRADIENT PUMP SYSTEM WITH BLENDING QUARTENARY VALVE AND TWO 8-PORT BUFFER INLETS

AUTOMATED BUFFER BLENDING COMBINED WITH AUTOMATED GRADIENTS USING A WIDE VARIETY OF BUFFERS FOR RAPID EXPANDED SCOUTING

Includes two gradient pumps, a mixer module, two inlet valves for automated buffer selection, and a quaternary valve for buffer-blending and scouting applications.

  • Available in 0.001–10 ml/min (max. 3,650 psi) and 0.01–100 ml/min (max. 1,450 psi) formats
  • Automated buffer gradient and buffer-blending capabilities
  • Buffer screening and gradient separations at different pH values
  • Additional inlets for buffer, cleaning, and storage solutions for fully automated workflows and walk-away convenience
  • Flow rates of up to 20 ml/min and 200 ml/min for the 10 ml/min and 100 ml/min pumps, respectively

DUAL-GRADIENT PUMP SYSTEM WITH TWO 8-PORT BUFFER INLETS

AUTOMATED BUFFER SELECTION AND SCOUTING

Includes two gradient pumps, a mixer module, and two inlet valves.

  • Available in 0.001–10 ml/min (max. 3,650 psi) and 0.01–100 ml/min (max. 1,450 psi) formats
  • Additional inlets for buffer and cleaning, and storage solutions for fully automated workflows and walk-away convenience

DUAL-GRADIENT PUMP SYSTEM WITH AN 8-PORT BUFFER INLET

AUTOMATED BUFFER SELECTION AND SCOUTING

Includes two gradient pumps, a mixer module, and a single inlet valve

  • Available in 0.001–10 ml/min (max. 3,650 psi) and 0.01–100 ml/min (max. 1,450 psi) formats
  • Additional inlets for buffer and cleaning, and storage solutions for fully automated workflows and walk-away convenience

MANUAL SAMPLE LOADING

SMALL SAMPLE VOLUME INJECTIONS USING FIXED OR DYNAMIC LOOPS

Includes an 8-port inject valve and a fixed sample loop.

  • Highly reproducible sample injections
  • Sample injection integrated into method
  • Multiple injections of different volumes using a dynamic loop

AUTOMATED SAMPLE LOADING

LARGE SAMPLE VOLUME INJECTIONS AND AUTOMATED REPEAT LOADING OF SAMPLES

Includes a sample pump with a pressure sensor.

  • Dedicated pump for loading sample, eliminating contamination of system pump
  • Automated loading of large volume samples either directly or via sample loops
  • Flow rate of up to 100 ml/min at 1,450 psi

AUTOSAMPLER

AUTOMATED INJECTION OF A WIDE VARIETY OF SAMPLES

Includes a C-96 autosampler and a sample carousel.

  • Various carousel types available based on the number and volume of samples
  • Automated loading of up to 96 samples in a sequence of experiments
  • Automated sample dilutions prior to loading

AUTOMATED SAMPLE LOADING WITH ONE 8-PORT SAMPLE INLET

LARGE SAMPLE VOLUME INJECTIONS AND AUTOMATED REPEAT LOADING OF SAMPLES

Includes an 8-port inject valve, a sample pump, a sample inlet valve, and a fixed loop.

  • Dedicated pump for loading sample, eliminating contamination of system pump
  • Sequential automated purification of up to 8 large volume samples
  • Automated sample selection of up to 8 samples by inlet valve
  • Flow rate of up to 100 ml/min at 1,450 psi
  • Coming soon

AUTOMATED SAMPLE LOADING WITH TWO 8-PORT SAMPLE INLETS

LARGE SAMPLE VOLUME INJECTIONS AND AUTOMATED REPEAT LOADING OF SAMPLES

Includes an 8-port inject valve, a sample pump, two sample inlet valves, and a fixed loop.

  • Dedicated pump for loading sample, eliminating contamination of system pump
  • Sequential automated purification of up to 15 large volume samples
  • Flow rate of up to 100 ml/min at 1,450 psi
  • Automated sample selection of up to 15 samples by two sample inlet valves
  • Coming soon

SINGLE COLUMN

CONNECTION TO ANY COLUMN AND MEDIA TYPE

For use with most commercially available self-packed, prepacked, glass, or stainless steel lab-scale columns or cartridges.

5-COLUMN SCOUTING / SCREENING

CONNECTION OF UP TO FIVE COLUMNS

Includes a 12-port column switching valve with reverse flow capability for increased flexibility in column and media selection.

  • Rapid screening of up to 5 columns and media in automated sequence
  • Reverse flow capability for concentrated fractions and column cleaning
  • Built-in pressure sensors protect columns from overpressurizing and compacting
  • Differential pressure sensing capability for monitoring column health

2 x 5-COLUMN SCOUTING / SCREENING

CONNECTING UP TO TEN COLUMNS AND PERFORMING TANDEM PURIFICATIONS

Includes two 12-port column switching valves with reverse flow capability for increased flexibility in column and media selection.

  • Rapid screening of up to 10 columns and media in automated sequence
  • Reverse flow capability for concentrated fractions and column cleaning
  • Built-in pressure sensors protect columns from overpressurizing and compacting
  • Differential pressure sensing capability for monitoring column health
  • Coming soon

3 x 5-COLUMN SCOUTING / SCREENING

CONNECTING UP TO 15 COLUMNS AND PERFORMING TANDEM PURIFICATIONS

Includes three 12-port column switching valves with reverse flow capability for increased flexibility in column and media selection.

  • Rapid screening of up to 15 columns and media in automated sequence
  • Reverse flow capability for concentrated fractions and column cleaning
  • Built-in pressure sensors protect columns from overpressurizing and compacting
  • Differential pressure sensing capability for monitoring column health
  • Coming soon

SINGLE-WAVELENGTH DETECTOR

LED-BASED SINGLE LIGHT SOURCE DETECTION WITH CONDUCTIVITY MONITORING

Includes a high-accuracy single-wavelength detector with integrated conductivity.

  • Long-life LED-based light source (255 and 280 nm)
  • Integrated conductivity detector (0.01–999 mS/cm)

MULTI-WAVELENGTH DETECTOR

SIMULTANEOUS FOUR-WAVELENGTH DETECTION WITH CONDUCTIVITY MEASUREMENT

Includes a four-wavelength detector with integrated conductivity.

  • 4 user-defined wavelengths (190–800 nm)
  • Integrated conductivity detector (0.01–999 mS/cm)
  • Detection of peptides, proteins, nucleic acids, and specific chromophores such as hemoglobin

SINGLE-WAVELENGTH DETECTOR WITH pH MONITORING

LED-BASED SINGLE LIGHT SOURCE DETECTION WITH CONDUCTIVITY AND pH MONITORING

Includes a high-accuracy single-wavelength detector with integrated conductivity and pH detector, and a valve.

  • Long-life LED-based light source (255 and 280 nm)
  • Integrated conductivity detector (0.01–999 mS/cm)
  • Full-range pH detection, includes pH probe and valve-based flow cell for convenient bypass, calibration, and storage

MULTI-WAVELENGTH DETECTOR WITH pH MONITORING

SIMULTANEOUS FOUR-WAVELENGTH DETECTION WITH CONDUCTIVITY AND pH MONITORING

Includes a four-wavelength detector with integrated conductivity and pH detector, and a valve.

  • 4 user-defined wavelengths (190–800 nm)
  • Detection of peptides, proteins, nucleic acids, and specific chromophores such as hemoglobin
  • Integrated conductivity detector (0.01–999 mS/cm)
  • Full-range pH detection, includes pH probe and valve-based flow cell for convenient bypass, calibration, and storage

BIOFRAC FRACTION COLLECTOR

IDEAL FOR ANALYTICAL AND PREPARATIVE CHROMATOGRAPHY APPLICATIONS

Includes a BioFrac fraction collector.

  • Basic or complex fraction collection schemes for flow rates of up to 100 ml/min.
  • Flexibility with numerous collection rack options such as microtiter plates, centrifuge tubes, 15 and 50 ml conical tubes, and bottles
  • Integrated valve for diverting flow to waste

BIOFRAC FRACTION COLLECTOR WITH ONE 12-PORT OUTLET

IDEAL FOR ANALYTICAL AND PREPARATIVE CHROMATOGRAPHY APPLICATIONS

Includes a BioFrac fraction collector and a 12-port outlet valve.

  • Basic or complex fraction collection for flow rates of up to 100 ml/min.
  • Flexibility with numerous collection rack options
  • Integrated valve for diverting flow to waste
  • Outlet valve for additional large volume collection options
  • Coming soon

BIOFRAC FRACTION COLLECTOR WITH TWO 12-PORT OUTLETS

IDEAL FOR ANALYTICAL AND PREPARATIVE CHROMATOGRAPHY APPLICATIONS

Includes a BioFrac fraction collector and two 12-port outlet valves.

  • Basic or complex fraction collection schemes for flow rates of up to 100 ml/min.
  • Flexibility with numerous collection rack options
  • Integrated valve for diverting flow to waste
  • Two outlet valves for maximum large volume collection options
  • Coming soon

LARGE VOLUME COLLECTION — ONE 12-PORT OUTLET

IDEAL FOR PREPARATIVE CHROMATOGRAPHY APPLICATIONS

Includes a single 12-port outlet valve.

  • Outlet valve for additional large volume collection options
  • Coming soon

LARGE VOLUME COLLECTION — TWO 12-PORT OUTLETS

IDEAL FOR PREPARATIVE CHROMATOGRAPHY APPLICATIONS

Includes two 12-port outlet valves.

  • Two outlet valves for maximum large volume collection options
  • Coming soon

NO COLLECTION OR EXISTING COLLECTOR

FOR ANALYTICAL APPLICATIONS WHERE FRACTION COLLECTION IS NOT REQUIRED OR AN EXISTING COLLECTOR IS PRESENT

Dual Gradient Pump System...